Anterior Eye Diseases
Eye Bank Screening
Glaucoma Imaging
Previous COOL News
COOL HomeResearchPeoplePublicationsPresentationsLinks

Eye Bank Cornea Screening with Optical Coherence Tomography (NIH R01EY017723)

 

The transplantation of donor cornea that has undergone refractive surgery (LASIK, RK, PRK) can lead to wound separation during surgery and to increased refractive error in the recipient. Therefore, the increasing popularity of refractive surgery has raised concerns about the decreasing proportion of transplant quality corneas coming in to the eye bank and the serious consequences of transplanting a post-refractive surgery cornea that has escaped detection.

Currently, eye banks use patient history and microscopic examination to assess the quality of donor corneas and detect previous refractive surgery. Although these methods can screening out many problem corneas, they are subject to human error. Patient history may be unreliable, and well-performed LASIK and PRK may leave minimal debris and scarring which can be particularly difficult to detect.

OCT performs 3-dimensional imaging of the cornea with micron resolution. It can visualize the corneal layers, detect opacities, and measure surface contours. Our preliminary studies showed that OCT can image donor corneal tissue without even removing it from the sterile container and preservation medium. The digital OCT data is amenable to automated image processing. These characteristics are ideal for a screening test. Therefore, our specific aims are to:

 

1. Develop a high performance OCT system for eye bank screening. Using the ultra-highspeed Fourier-domain OCT technology, the system will provide detailed 3-D scanning within 3 minutes.

2. Develop OCT to detect previous refractive surgery. Our preliminary data showed that OCT can detect topographic and reflectivity changes in the post-LASIK cornea. We will develop image processing algorithms to detect LASIK, PRK, RK, and any surgery that modifies corneal curvature.

3. Develop OCT to assess donor corneal quality. We will develop criteria to automatically quantify corneal quality indicators: topographic regularity, epithelial sloughing, stromal opacity/edema, and endothelial striae.

4. Develop OCT to measure donor cornea power to improve refractive outcome of transplant surgery.

If successful, we will safeguard the future supply of donor corneal tissue for transplantation by offering an objective and reliable screening method that adds minimal time and cost to eye bank procedures.


RSS